Пеногенерирующие системы со сжатым воздухом – средство пенного пожаротушения нового поколения

Authors

  • Oleg D. Navrotskiy State Educational Establishment «Institute for Command Engineers» of the Ministry of Emergency Situations of the Republic of Belarus; 220118, Belarus, Minsk, ul. Mashinostroiteley, 25
  • Yu.V. Zanevskaya Research Institute of Fire Safety and Emergencies of the Ministry for Emergency Situations of the Republic of Belarus; 220050, Belarus, Minsk, ul. Soltysa, 183a
  • V.K. Emel'yanov Research Institute of Fire Safety and Emergencies of the Ministry for Emergency Situations of the Republic of Belarus; 220050, Belarus, Minsk, ul. Soltysa, 183a
  • Andrey N. Kamlyuk State Educational Establishment «Institute for Command Engineers» of the Ministry of Emergency Situations of the Republic of Belarus; 220118, Belarus, Minsk, ul. Mashinostroiteley, 25 https://orcid.org/0000-0002-9347-0778
  • Igor' V. Karpenchuk State Educational Establishment «Institute for Command Engineers» of the Ministry of Emergency Situations of the Republic of Belarus; 220118, Belarus, Minsk, ul. Mashinostroiteley, 25
  • Aleksandr V. Grachulin State Educational Establishment «Institute for Command Engineers» of the Ministry of Emergency Situations of the Republic of Belarus; 220118, Belarus, Minsk, ul. Mashinostroiteley, 25

Abstract

Performance characteristics, advantages of application and variety of compressed air foam systems (CAFS) are given. The work describes the mathematical model of movement of gas-water mix at one-dimensional movement. The results of research of properties of foam generated by CAFS «80-40-E WATEROUS» are submitted. The comparison of time of extinguishing, number of spent fire extinguishing agents, intensity of supply of the water solution of blowing agent to extinguish model fire source of class A by foam generated by CAFS «80-40-E WATEROUS» and fire nozzle of type SVP-2 are presented.

Author Biographies

Oleg D. Navrotskiy, State Educational Establishment «Institute for Command Engineers» of the Ministry of Emergency Situations of the Republic of Belarus; 220118, Belarus, Minsk, ul. Mashinostroiteley, 25

PhD in Technical Sciences

Yu.V. Zanevskaya, Research Institute of Fire Safety and Emergencies of the Ministry for Emergency Situations of the Republic of Belarus; 220050, Belarus, Minsk, ul. Soltysa, 183a

PhD in Chemical Sciences

Andrey N. Kamlyuk, State Educational Establishment «Institute for Command Engineers» of the Ministry of Emergency Situations of the Republic of Belarus; 220118, Belarus, Minsk, ul. Mashinostroiteley, 25

PhD in Physical and Mathematical Sciences, Associate Professor

Igor' V. Karpenchuk, State Educational Establishment «Institute for Command Engineers» of the Ministry of Emergency Situations of the Republic of Belarus; 220118, Belarus, Minsk, ul. Mashinostroiteley, 25

PhD in Technical Sciences, Associate Professor

References

Carey, W.M. National class A foam research project technical report: Structural fire fighting--room burn tests phase II / W.M. Carey // MA: National Fire Protection Research Foundation. – 1994.

Colletti, D. J. Class A foam for structure firefighting / D. J. Colletti // Fire Engineering, 145. – 1992, July. – P. 47-56.

Liebson, J. Introduction to class A foams and compressed air foam systems for the structural fire service / J. Liebson // MA: International Society of Fire Service Instructors. –1991. – P. 45.

Colletti, D. J. Compressed air foam systems and fire hose / D. J. Colletti // Fire Engineering, 149. – 1996, July. – P. 50-52.

Murdock, J. I. Compressed air foam systems: A project pertaining to an adoption decision. (Executive Development Research Paper) / J. I. Murdock // Emmitsburg, MD: National Fire Academy. – 1997.

Promesis research project 2008 [Electronic resource]. – 2006. – Mode of access: http://www.firetactics.com/CAFS.htm. – Date of access : 06.03.2009.

Features and Benefits of Darley Auto Compressed Air Foam [Electronic resource]. – 2009. – Mode of access: http://www.darley.com/pumps/cafs/features.html. – Date of access : 06.03.2009.

Taylor, Robert G. Technical Report 98: Compressed Air Foam Systems in Limited Staffing Conditions / Robert G. Taylor. - Morristown, New Jersey, 1998. – P. 75–112.

Colletti, D. J. Testing CAFS in live burns / D. J. Colletti // Fire Engineering, 147. – 1994, July. – P. 74–76.

Fornell, D. P. Fire stream management handbook / D. P. Fornell // NJ: Fire Engineering. – 1991.

Интернет-портал [Электронный ресурс]. – Режим доступа: http://www.waterousco.com.

Кутателадзе С.С., Стырикович М.А. Гидродинамика газожидкостных систем. – М.: Энергия, 1976. – 296 с.

Уилкинсон У.Л. Неньютоновские жидкости. – М.: Мир, 1964.

Downloads


Abstract views: 129
PDF Downloads: 32

Published

2012-03-11

How to Cite

Navrotskiy О., Zanevskaya Ю., Emel’yanov В., Kamlyuk А., Karpenchuk И. and Grachulin А. (2012) “Пеногенерирующие системы со сжатым воздухом – средство пенного пожаротушения нового поколения”, Vestnik of the Institute for Command Engineers of the MES of the Republic of Belarus, 15(1), pp. 22–31. Available at: https://journals.ucp.by/index.php/vice/article/view/391 (Accessed: 25 December 2024).

Most read articles by the same author(s)