Snow load emergency situations prevention with the monitoring system equipment for steel horizontal structures

Authors

  • Valeriy S. Rudol'f State Educational Establishment «University of Сivil Protection of the Ministry for Emergency Situations of the Republic of Belarus»; ul. Mashinostroiteley, 25, Minsk, 220118, Belarus
  • Aleksandr A. Kondratovich State Educational Establishment «University of Сivil Protection of the Ministry for Emergency Situations of the Republic of Belarus»; ul. Mashinostroiteley, 25, Minsk, 220118, Belarus
  • Andrey A. Kaminskiy State Educational Establishment «University of Сivil Protection of the Ministry for Emergency Situations of the Republic of Belarus»; ul. Mashinostroiteley, 25, Minsk, 220118, Belarus
  • Andrey V. Surikov State Educational Establishment «University of Сivil Protection of the Ministry for Emergency Situations of the Republic of Belarus»; ul. Mashinostroiteley, 25, Minsk, 220118, Belarus
  • Vadim A. Kudryashov State Educational Establishment «University of Сivil Protection of the Ministry for Emergency Situations of the Republic of Belarus»; ul. Mashinostroiteley, 25, Minsk, 220118, Belarus

DOI:

https://doi.org/10.33408/2519-237X.2018.2-1.53

Keywords:

emergencies, roofing, roof covering, failure, snow load, actions, deformations, monitoring system, experimental studies

Abstract

Purpose. The article is devoted to snow load emergency situations prevention using the laser rangefinder monitoring system equipment for steel horizontal structures.

Methods. Experimental and theoretical studies on the steel roof truss deflections under snow load using the monitoring system equipment.

Findings. It was found that the steel roof truss deflections under snow load, obtained with the laser rangefinder monitoring system equipment Sense S-One, correspond to the data of a more accurate measuring instrument – a TST (total station theodolite), and conform satisfactorily with the calculation results.

Conclusions. The values of the laser rangefinder monitoring system data correspond to the data of a more accurate measuring instrument – a TST (total station theodolite). It might be mentioned that the error of the laser rangefinder monitoring system does not allow to evaluate the results with a value (or step) less than 2.0 mm. The calculated deflection in comparison with the experimental data was constantly 44 % higher, which indicates a correlation between the calculation results and experiment. Higher calculated values of deflection are acceptable, because they are obtained for idealized hinge support conditions and give a safety margin.

Author Biographies

Valeriy S. Rudol'f, State Educational Establishment «University of Сivil Protection of the Ministry for Emergency Situations of the Republic of Belarus»; ul. Mashinostroiteley, 25, Minsk, 220118, Belarus

начальник филиала

Aleksandr A. Kondratovich, State Educational Establishment «University of Сivil Protection of the Ministry for Emergency Situations of the Republic of Belarus»; ul. Mashinostroiteley, 25, Minsk, 220118, Belarus

Branch IRPD, Chair of Professional Development, Professor; PhD in Technical Sciences, Associate Professor

Andrey A. Kaminskiy, State Educational Establishment «University of Сivil Protection of the Ministry for Emergency Situations of the Republic of Belarus»; ul. Mashinostroiteley, 25, Minsk, 220118, Belarus

заместитель начальника филиала

Andrey V. Surikov, State Educational Establishment «University of Сivil Protection of the Ministry for Emergency Situations of the Republic of Belarus»; ul. Mashinostroiteley, 25, Minsk, 220118, Belarus

Branch IRPD, Chair of Professional Development, Head of Chair

Vadim A. Kudryashov, State Educational Establishment «University of Сivil Protection of the Ministry for Emergency Situations of the Republic of Belarus»; ul. Mashinostroiteley, 25, Minsk, 220118, Belarus

Department of Scientific and Innovation Activity, Head of Department of Scientific and Innovation Activity; PhD in Technical Sciences, Associate Professor

References

Dzhambulatov R.G. Analiz prichin obrusheniya pokrytiy obshchestvennykh zdaniy [Analysis of the causes of collapse of public building coverings]. Molodoy uchenyy, 2015. No. 10. Pp. 197-200. (rus)

Biegus A., Rykaluk K. Collapse of Katowice fair building. Engineering Failure Analysis. 2013. No. 16 (5). Рр. 1643–1654.

Holicky M., Sykora M. Failures of roofs under snow load: Causes and reliability analysis. In Proc. Fifth Congress on Forensic Engineering. 2009. Рp. 11–14.

Stroitel'nye normy i pravila. Nagruzki i vozdeystviya [Building regulations. Loads and impacts]: SNiP 2.01.07-85. Implemented on 01/01/1987. Moscow: USSR State Construction Committee. 1987. 46 p. (rus)

Eurocode 1. Impact on the structure. Part 1-3. General effects. Snow loads: Technical Code of Good Practice EN 1991-1-3-2009 (02250). Implemented on 01/01/2010. Minsk: Ministry of Architecture. 2009. 48 p.

Eurocode. Fundamentals of structural design (EN 1990: 2002, IDT): Technical Code of Good Practice EN 1990-2011* (02250). Implemented on 01/07/2012. Re-issue with Amendment No. 1 (Implemented on 04/01/2015). Minsk: Ministry of Architecture. 2015. 94 p.

Building regulations. Loads and impacts: Ammendment No. 1 to SNIP 2.01.07-85. Implemented on 01/07/2004. Minsk: Ministry of Architecture. 2004. 5 p.

Maps of the regionalization of the territory of the USSR on climatic characteristics: Appendix 5 to SNIP 2.01.07-85. Implemented on 01/01/1987. Moscow: Gosstroy USSR. 1987. 9 p.

Eurocode 1. Impact on the structure. Part 1–3. General effects. Snow loads: Amendment No. 2 to the Technical Code of Good Practice EN 1991-1-3-2009 (02250). Implemented on 07/01/2015. Minsk: Ministry of Architecture. 2015. 9 p.

Technical operation of industrial buildings and structures. Order of conduct: Technical Code of Good Practice 45-1.04-78-2007 (02250). Implemented on 01/04/2008. Minsk: Ministry of Architecture. 2008. 56 p.

Technical operation of residential and public buildings and structures. Order of conduct: Technical Code of Good Practice 45-1.04-14-2005 (02250). Implemented on 01/07/2006. Minsk: Ministry of Architecture. 2006. 44 p.

Eurocode 2. Design of reinforced concrete structures. Part 1-1. General rules and rules for buildings (EN 1992-1-1: 2004 + AC: 2010, IDT): Technical Code of Good Practice EN 1992-1-1-2009* (02250). Implemented on 01/01/2010. Re-issue with Amendment No. 1 (Implemented on 04/01/2015). Minsk: Ministry of Architecture. 2015. 219 p.

Eurocode 5. Design of wooden structures. Part 1-1. General rules and rules for buildings (EN 1995-1-1: 2004 + AC: 2006 + A1: 2008, IDT): Technical Code of Good Practice EN 1995-1-1-2009* (02250). Implemented on 01/01/2010. Re-issue with Amendment No. 1 (Implemented on 01/09/2014). – Minsk: Ministry of Architecture. 2014. 106 p.

Eurocode 3. Design of steel structures. Part 1-1. General rules and rules for buildings (EN 1993-1-1: 2005 + AC: 2009, IDT): Technical Code of Good Practice EN 1993-1-1-2009* (02250). Implemented on 01/01/2010. – Re-issue with Amendment No. 1 (Implemented on 01/09/2014). Minsk: Ministry of Architecture. 2014. 96 p.

Bases for the design of structures: ISO 4356 : 1977. Publication date: 1977-11. Geneva: ISO. 1977. 18 p.

Loads and effects (Additions, Section 10. Deflections and Displacements): SNiP 2.01.07-85. Implemented on 01/01/1987. Moscow: TsITP Gosstroy USSR, 1988. 8 p.

Martins N., Caetano E., Diord S. Dynamic monitoring of a stadium suspension roof: Wind and temperature influence on modal parameters and structural response. Engineering Structures. 2014. No. 59. Рp. 80–94.

The indoor stadium of JSC «Sports Complex Olympic», availiable at: http://www.inkommet.ru/drupal/olimp (accessed: November 10, 2017). (rus)

Typical documentation for structures, products and units of buildings and structures. 1.460.3-14. Steel structures of coatings of industrial buildings with spans of 18, 24 and 30 m with the use of closed bent welded profiles of rectangular cross section of the «Molodechno» type. Drawings of CM. Implemented on 06/01/1982. Leningrad: Gosstroy USSR GPI Lenstroiproektstalkonstruktsiya. 1982. 135 p.

Profiles steel curved closed welded square and rectangular for building constructions: GOST 30245-2003. Interstate Standard. Implemented on 01/10/2003. Moscow: Interstate Scientific and Technical Commission for Standardization, Technical Regulation and Certification in Construction. 2001. 8 p.

Rolled steel for construction steel structures. General specifications: GOST 27772-88. State standard. Implemented on 01/01/1969. Minsk: Publishing house of standards. 1990. 28 p.

Downloads


Abstract views: 306
PDF Downloads: 174

Published

2018-02-15

How to Cite

Rudol’f В., Kondratovich А., Kaminskiy А., Surikov А. and Kudryashov В. (2018) “Snow load emergency situations prevention with the monitoring system equipment for steel horizontal structures”, Journal of Civil Protection, 2(1), pp. 53–66. doi: 10.33408/2519-237X.2018.2-1.53.

Most read articles by the same author(s)