Tabular data for estimating the fire resistance of bendable steel beams without fire protection
DOI:
https://doi.org/10.33408/2519-237X.2022.6-1.58Keywords:
unprotected steel structures, limit load, yield strength, loadAbstract
Purpose. The development of tabular data for estimating the fire resistance of bendable steel beams, taking into account the given level of loading.
Methods. The analytical solution of thermal and static problems of fire resistance of bendable steel structures.
Findings. For the range of steel W shaped I-beams (normal and wide flange according to STO ASCHM 20-93) from steel grades S245, S255, S285, S345 load limits are determined (depending on the span, section class and working conditions of the structure) at which the beam can be used in a building without fire protection, providing fire resistance of 15 and 30 minutes. Based on the calculations, tabular data were developed to assess the fire resistance of steel beams without fire protection.
Application field of research. The results obtained can be used to solve the problems of fire resistance of bendable steel beams, taking into account the load while designing and constructing buildings and structures.
References
Roytman V.M. Fizicheskiy smysl i otsenka koeffitsienta usloviy raboty i kriticheskoy temperatury progreva materialov konstruktsiy v usloviyakh pozhara [The physical meaning and evaluation of the coefficient of working conditions and the critical temperature of heating of structural materials in fire conditions]. Fire and Explosion Safety, 2011. Vol. 20, No. 5. Pp. 14–21. (rus)
Zhamoydik S.M. Metodologiya otsenki ognestoykosti stal'nykh kolonn s konstruktivnoy ognezashchitoy, raspolozhennykh po perimetru pomeshcheniya [Methodology of fire resistance evaluation of steel columns with fire structural protection, located on the perimeter of the premises]. Vestnik Komandno-inzhenernogo instituta MChS Respubliki Belarus', 2016. No. 2 (24). Pp. 39–51. (rus)
Vatikhova L., Kalafat K. Katalog sredstv ognezashchity stal'nykh konstruktsiy 2015 [Catalog of means of fire protection of steel structures 2015]. Kiev: Ukrainian Steel Construction Center, 2015. 117 p. (rus)
Zvezdov A.I., et al. Posobie po opredeleniyu predelov ognestoykosti stroitel'nykh konstruktsiy, parametrov pozharnoy opasnosti materialov. Poryadok proektirovaniya ognezashchity [Manual for determining the fire resistance limits of building structures, parameters of fire hazard of materials. Design procedure for fire protection]. Moscow: Research Center Construction, 2013. 45 p. (rus)
Bessonov N.M., Eremina T.Yu., Dmitrieva Yu.N., Krasheninnikova M.V. Raschetnyy metod opredeleniya predelov ognestoykosti metallokonstruktsiy, pokrytykh ognezashchitnym vspuchivayushchimsya sostavom [Calculation method for determining the limits of fire resistance of metal structures coated with a flame retardant swelling compound]. Fire Safety, 2007. No. 1. Pp. 89–96. (rus)
Botyan S.S., Zhamoydik S.M., Kudryashov V.A., Olesiyuk N.M. Progrev sterzhnevykh stal'nykh konstruktsiy s chastichnoy i polnoy ognezashchitoy naruzhnoy poverkhnosti pri ognevom vozdeystvii [Heating of rod steel structures with partial and full fire-protected external surface under fire exposure]. Journal of Civil Protection, 2020. Vol. 4, No. 1. Pp. 20–31. (rus). DOI: https://www.doi.org/10.33408/2519-237X.2020.4-1.20.
Basakovich I.A, Batyan S.S., Zhamoydik S.M., Kudryashov V.A., Osyaev V.A., Polevoda I.I. Ognezashchitnaya effektivnost' gipsovykh plit KNAUF FIREBOARD dlya vertikal'nykh stal'nykh profiley razlichnogo sortamenta [Knauf Fireboard fire protection efficiency for vertical steel profiles of various cross section shapes]. Journal of Civil Protection, 2019. Vol 3, No. 3. Pp. 268–282. (rus). DOI: https://www.doi.org/10.33408/2519-237X.2019.3-3.268.
Published
How to Cite
License
Copyright (c) 2022 Zhamoydik S.M., Shkaradenok K.V., Lyashchenko S.F.
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.